Platform · Surveys

Field capture that survives the field

Surveyors capture everything offline — components, HHSRS issues and photos — in basements, stairwells and dead-signal estates. Nothing is lost, nothing overwrites the master, and nothing reaches the live record until it passes QA.

app.clearviewams.com/surveys
Asset overview

Surveys accepted

1,284+12.4%

Decent Homes compliant

94.2%+1.8%

HHSRS Cat 1 open

7−3

Awaiting QA

231.2d avg

Surveys synced

7,940 9.1%
JanFebMarAprMayJunJulAugSepOctNovDec
Offline captureAvailable now

Capture anything offline

The device is the source of truth during fieldwork. Open, answer, photograph and draft with no connection — then sync when signal returns.

  • Works with no signal

    A template-driven survey runs entirely on-device — no connection required to capture a thing.

  • Drafts & photos survive restart

    Close the app, lose battery, come back tomorrow — your in-progress survey is exactly where you left it.

  • Required-vs-observed prompts

    A missing CO or smoke alarm raises a pre-filled issue on the spot, so safety gaps are never quietly skipped.

9:41
All surveys

12 Vicarage Lane

Services & safety

5/8

Boiler / heating condition

Fair

Electrical installation condition

Good

CO alarm fitted & working

Required where combustion appliances are present.

CO alarm missing or not working Raise issue

Smoke alarm fitted & working

Fire door self-closer functioning

BackNext
EvidenceAvailable now

Evidence bound to the record

Photos attach to the exact question, component or issue they evidence — never a loose gallery. Provenance travels with every image.

  • Photos tied to the record

    Each photo is parent-linked to its question, component, issue or access event — traceable forever.

  • Named-user provenance

    Captured-at and uploaded-at timestamps, the surveyor and the device travel with every record.

  • Embedded in the report

    Photos appear in the PDF beside the record they evidence, and in the structured export by stable key.

9:41
All surveys

12 Vicarage Lane

Kitchen

3/8

Kitchen 1

Condition

Fair

Observed remaining life

6 yrs

Estimated renewal year

2031

Notes

Worktop edges swelling near sink.

1 photo · queued
BackNext
HHSRS & QAAvailable now

Issues, HHSRS & the QA gate

Every defect is a typed issue record. Surveys are point-in-time snapshots — they only update the live master after an independent reviewer accepts them.

  • Issue-level HHSRS

    Category 1 / Category 2 hazards with controlled reason codes, linked to the component and the question that raised them.

  • No silent overwrite

    Master-version conflict control blocks and logs any push that would clobber a changed record.

  • Maker-checker QA

    Accept or reject with comments. Rejections return to the surveyor editable; acceptances promote to the live record and the export.

9:41
All surveys

12 Vicarage Lane

Issues & HHSRS

7/8
!HHSRS· Category 1ISS-0042

Bathroom 2 — north wall

Investigate & treat damp / mould

!Urgent review· Cat 1 concernISS-0043

Kitchen 1 — combustion

CO alarm missing — fit immediately

!RepairISS-0044

Kitchen 1 — worktop

Renew worktop run

Add issue
BackNext

See offline capture survive the field

We'll go offline mid-survey on a real batch of your stock — and show nothing is lost, nothing is overwritten, and everything reconciles.